Review



gene pulser xcelltm transfection apparatus  (Bio-Rad)


Bioz Verified Symbol Bio-Rad is a verified supplier
Bioz Manufacturer Symbol Bio-Rad manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 97

    Structured Review

    Bio-Rad gene pulser xcelltm transfection apparatus
    Gene Pulser Xcelltm Transfection Apparatus, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 97/100, based on 5921 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/gene+pulser+transfection+apparatus/Gene+Pulser+Xcell+Total+System/us11970542-645-27-32
    Average 97 stars, based on 5921 article reviews
    gene pulser xcelltm transfection apparatus - by Bioz Stars, 2026-09
    97/100 stars

    Images

    Related Articles

    Transfection:

    Article Title: Fertile transgenic plants obtained from tritordeum inflorescences by tissue electroporation.
    Article Snippet: P.A.. Lazzeri DuPont Wheat Transformation Laboratory, C/O IACR-Rothamsted, Harpenden, Herts, AL5 2JQ, UK Abstract Tissue electroporation was applied to a member of the Triticeae family, namely tritordeum (Hordeum chilense Roem.. !Triticum turgidum L. Conv. durum), for the generation of fertile transgenic plants.

    Article Title: GSK3β Serine 389 Phosphorylation Modulates Cardiomyocyte Hypertrophy and Ischemic Injury.
    Article Snippet: 2021, 22, 13586 12 of 17 electroporation competent cells BJ5183-AD-1 (Stratagene, Agilent Technologies). .. Electroporation was performed using Gene Pulser Transfection Apparatus (Bio-Rad, Hercules, CA, USA) at 2500 V, 200 Ω and 25 μF. ..

    Article Title: SIRT3 increases cisplatin sensitivity of small-cell lung cancer through apoptosis.
    Article Snippet: Small-cell lung cancer (SCLC) is the most invasive of all lung cancer subtypes, and is characterized by its rapid response to chemotherapy resistance.. Overcoming chemotherapy resistance is therefore the key to treating SCLC.. P53 is mutated in most SCLCs, which has an effect of enhancing chemotherapy resistance.

    Article Title: Urea transport B gene induces melanoma B16 cell death via activation of p53 and mitochondrial apoptosis
    Article Snippet: .. We used the Gene Pulser Transfection Apparatus (Bio‐Rad, 1652100, California, USA) to transfer plasmids into competent attenuated S. typhimurium . ..

    Article Title: Contribution of muscarinic receptors to in vitro and in vivo effects of Ruscus extract.
    Article Snippet: Article history: Received 9 April 2017 Accepted 17 May 2017 Available online 19 May 2017 The objectives of this study were to evaluate, in vitro and in vivo, the contribution of muscarinic receptors to the effects of Ruscus extract.. Ruscus extract was tested in competition binding experiments at recombinant humanmuscarinic receptors, heterologous expressed in Chinese Hamster Ovary (CHO) cells and in cellular assays measuring Ca liberation and activator protein-1 (AP-1) reporter gene activation.. The impact of muscarinic blockade on prolonged treatment outcomewas evaluated using the hamster cheek pouch (HCP) microcirculation examining macromolecular permeability increase induced by histamine or ischemia/reperfusion (I/R), mean arteriolar and venular diameters, functional capillary density and I/R-induced leukocyte rolling and sticking.

    Article Title: Structural determinants of pure antiestrogenicity
    Article Snippet: For each condition, 5 x 10 6 cells were added to a DNA mix containing the luciferase reporter vector pGL3-ERE3-TATA-Luc (2 μg), the pSG5-ERα expression vector or empty parental vector (1 μg), a GFP internal control expression plasmid (0.5 μg) and salmon sperm DNA to 40 ug DNA total. .. This mixture was transferred into an electroporation cuvette (Biorad) and electroporated at 240V/950 μF using a Gene Pulser Transfection Apparatus (Biorad). ..

    Article Title: Sumoylation of Notch1 represses its target gene expression during cell stress
    Article Snippet: Transfection was performed by resuspending 10 μg of plasmid DNA, and HeLa or COS7 or HEK 293 FLN cells in 400 μl Opti-MEM (Invitrogen) in BTX cuvettes. .. Cells were subjected to electroporation at 220 V and 975 μF (Gene Pulser Transfection Apparatus, Bio-Rad). ..

    Article Title: Sirtuin 3 induces apoptosis and necroptosis by regulating mutant p53 expression in small‑cell lung cancer.
    Article Snippet: .. The cuvette was placed in a Gene Pulser Transfection Apparatus (product no. 1652100; Bio-Rad Laboratories, Inc.), and pulsed once. ..

    Electroporation:

    Article Title: GSK3β Serine 389 Phosphorylation Modulates Cardiomyocyte Hypertrophy and Ischemic Injury.
    Article Snippet: 2021, 22, 13586 12 of 17 electroporation competent cells BJ5183-AD-1 (Stratagene, Agilent Technologies). .. Electroporation was performed using Gene Pulser Transfection Apparatus (Bio-Rad, Hercules, CA, USA) at 2500 V, 200 Ω and 25 μF. ..

    Article Title: SIRT3 increases cisplatin sensitivity of small-cell lung cancer through apoptosis.
    Article Snippet: Small-cell lung cancer (SCLC) is the most invasive of all lung cancer subtypes, and is characterized by its rapid response to chemotherapy resistance.. Overcoming chemotherapy resistance is therefore the key to treating SCLC.. P53 is mutated in most SCLCs, which has an effect of enhancing chemotherapy resistance.

    Article Title: Structural determinants of pure antiestrogenicity
    Article Snippet: For each condition, 5 x 10 6 cells were added to a DNA mix containing the luciferase reporter vector pGL3-ERE3-TATA-Luc (2 μg), the pSG5-ERα expression vector or empty parental vector (1 μg), a GFP internal control expression plasmid (0.5 μg) and salmon sperm DNA to 40 ug DNA total. .. This mixture was transferred into an electroporation cuvette (Biorad) and electroporated at 240V/950 μF using a Gene Pulser Transfection Apparatus (Biorad). ..

    Article Title: Sumoylation of Notch1 represses its target gene expression during cell stress
    Article Snippet: Transfection was performed by resuspending 10 μg of plasmid DNA, and HeLa or COS7 or HEK 293 FLN cells in 400 μl Opti-MEM (Invitrogen) in BTX cuvettes. .. Cells were subjected to electroporation at 220 V and 975 μF (Gene Pulser Transfection Apparatus, Bio-Rad). ..

    Plasmid Preparation:

    Article Title: SIRT3 increases cisplatin sensitivity of small-cell lung cancer through apoptosis.
    Article Snippet: Small-cell lung cancer (SCLC) is the most invasive of all lung cancer subtypes, and is characterized by its rapid response to chemotherapy resistance.. Overcoming chemotherapy resistance is therefore the key to treating SCLC.. P53 is mutated in most SCLCs, which has an effect of enhancing chemotherapy resistance.

    Bacteria:

    Article Title: SIRT3 increases cisplatin sensitivity of small-cell lung cancer through apoptosis.
    Article Snippet: Small-cell lung cancer (SCLC) is the most invasive of all lung cancer subtypes, and is characterized by its rapid response to chemotherapy resistance.. Overcoming chemotherapy resistance is therefore the key to treating SCLC.. P53 is mutated in most SCLCs, which has an effect of enhancing chemotherapy resistance.



    Similar Products

    97
    Bio-Rad gene pulser xcelltm transfection apparatus
    Gene Pulser Xcelltm Transfection Apparatus, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/gene+pulser+transfection+apparatus/Gene+Pulser+Xcell+Total+System/us11970542-645-27-32
    Average 97 stars, based on 1 article reviews
    gene pulser xcelltm transfection apparatus - by Bioz Stars, 2026-09
    97/100 stars
      Buy from Supplier

    90
    Bio-Rad gene pulser transfection apparatus
    Gene Pulser Transfection Apparatus, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/gene+pulser+transfection+apparatus/gene+pulser+transfection+apparatus/bio_rxiv__2023__10__31__564979-201-16-20
    Average 90 stars, based on 1 article reviews
    gene pulser transfection apparatus - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Bio-Rad gene-pulser transfection apparatus
    Gene Pulser Transfection Apparatus, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/gene+pulser+transfection+apparatus/Gene+Pulser%2FMicroPulser+Cuvette/pmc03204966-162-17-17
    Average 90 stars, based on 1 article reviews
    gene-pulser transfection apparatus - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Bio-Rad electroporator gene pulser transfection apparatus
    Electroporator Gene Pulser Transfection Apparatus, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/gene+pulser+transfection+apparatus/Electroporation+Cuvettes+For+Gene+Pulser+%2FMicro+Pulser/pmc03586085-42-5-10
    Average 90 stars, based on 1 article reviews
    electroporator gene pulser transfection apparatus - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    XINYI BIOTECHNOLOGY CO LTD gene pulser transfection apparatus xinyi-2e
    Gene Pulser Transfection Apparatus Xinyi 2e, supplied by XINYI BIOTECHNOLOGY CO LTD, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/gene+pulser+transfection+apparatus/gene+pulser+transfection+apparatus+xinyi+2e/pmc09223153-65-20-24
    Average 90 stars, based on 1 article reviews
    gene pulser transfection apparatus xinyi-2e - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Bio-Rad gene pulser ii transfection apparatus
    Gene Pulser Ii Transfection Apparatus, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/gene+pulser+transfection+apparatus/Electroporation+Cuvettes+For+Gene+Pulser+%2FMicro+Pulser/pm32870485-81-14-19
    Average 90 stars, based on 1 article reviews
    gene pulser ii transfection apparatus - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results